当前位置: 首页 > 协会标准 > ASTM 美国材料与试验协会 > ASTM D6760-2008 用超声波孔间试验测试混凝土深地基完整性的标准试验方法
ASTM D6760-2008 用超声波孔间试验测试混凝土深地基完整性的标准试验方法

ASTM D6760-2008 用超声波孔间试验测试混凝土深地基完整性的标准试验方法

prev next

  • 商品货号:INFOEACH_80915
  • 商品品牌:美国材料与试验协会 ASTM
    商品重量:0克
  • 上架时间:2021-03-03
    商品点击数:5676
  • 用户评价: comment rank 5
  • 本店售价:请咨询客服
  • 点击此处进入论坛自助下载

资料描述

【英文标准名称】: Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing
【原文标准名称】: 用超声波孔间试验测试混凝土深地基完整性的标准试验方法
【标准号】: ASTM D6760-2008
【标准状态】: 现行
【国别】: 美国
【发布日期】: 2008
【实施或试行日期】:
【发布单位】: 美国材料与试验协会(US-ASTM)
【起草单位】: D18.11
【标准类型】: (Test Method)
【标准水平】: ()
【中文主题词】:
【英文主题词】: barrette; bored pile; crosshole sonic logging; crosshole testing; drilled shaft; integrity test; single hole ultrasonic testing; ultrasonic logging; ultrasonic testing; Barettes; Borehole drilling; Crosshole testing; Drilled concrete cores; Integrity test
【摘要】: This method uses data from ultrasonic probes lowered into parallel access ducts, or in a single access duct, in the deep foundation element to assess the homogeneity and integrity of concrete between the probes. The data are used to confirm adequate concrete quality or identify zones of poor quality. If defects are detected, then further investigations should be made by excavation or coring the concrete as appropriate, or by other testing such as Test Method D 1143, D 4945 or D 5882, and measures taken to remediate the structure if a defect is confirmed. Note 18212;The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D 3740 are generally considered capable of competent and objective testing and inspection. Users of this standard are cautioned that compliance with Practice D 3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D 3740 provides a means of evaluating some of those factors.1.1 This test method covers procedures for checking the homogeneity and integrity of concrete in deep foundation such as bored piles, drilled shafts, concrete piles or augercast piles. This method can also be extended to diaphragm walls, barrettes, dams etc. In this test method, all the above will be designated x201C;deep foundation elements.x201D; The test measures the propagation time and relative energy of an ultrasonic pulse between parallel access ducts (crosshole) or in a single tube (single hole) installed in the deep foundation element. This method is most applicable when performed in tubes that are installed during construction. 1.2 Similar techniques with different excitation sources exist, but these techniques are outside the scope of this test method. 1.3 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026. 1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope. 1.4 The method used to specify how data are collected, calculated, or recorded in this test method is not directly related to the accuracy to which data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope. 1.5 This standard provides minimum requirements for crosshole (or single hole) testing of concrete deep foundation elements. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test(s), may provide additional requirements and procedures as needed to satisfy the objectives of a particular test program. 1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 Limitations8212;Proper installation of the access ducts is essential for effective testing and interpretation. The method does not give the exact type of defect (for......
【中国标准分类号】: P22
【国际标准分类号】: 91_080_40
【页数】: 7P.;A4