当前位置: 首页 > 协会标准 > ASTM 美国材料与试验协会 > ASTM E264-2008 通过镍的放射性测量快中子反应速率的试验方法
ASTM E264-2008 通过镍的放射性测量快中子反应速率的试验方法

ASTM E264-2008 通过镍的放射性测量快中子反应速率的试验方法

prev next

  • 商品货号:INFOEACH_80742
  • 商品品牌:美国材料与试验协会 ASTM
    商品重量:0克
  • 上架时间:2021-03-04
    商品点击数:5632
  • 用户评价: comment rank 5
  • 本店售价:请咨询客服
  • 点击此处进入论坛自助下载

资料描述

【英文标准名称】: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel
【原文标准名称】: 通过镍的放射性测量快中子反应速率的试验方法
【标准号】: ASTM E264-2008
【标准状态】: 现行
【国别】: 美国
【发布日期】: 2008
【实施或试行日期】:
【发布单位】: 美国材料与试验协会(US-ASTM)
【起草单位】: E10.05
【标准类型】: (Test Method)
【标准水平】: ()
【中文主题词】:
【英文主题词】: activation; activation reaction; cross section; dosimetry; fast-neutron monitor; neutron metrology; nickel; pressure vessel surveillance; reaction rate; Fast neutron flux/fluence; Neutron activation reactions; Nickel; Nickel alloys; Radioactivation--fast
【摘要】: Refer to Guide E 844 for the selection, irradiation, and quality control of neutron dosimeters. Refer to Practice E 261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. Pure nickel in the form of foil or wire is readily available, and easily handled. 58Co has a half-life of 70.86 days and emits a gamma ray with an energy of 0.8107593-MeV. Competing activities 65Ni(2.5172 h) and 57Ni(35.60 h) are formed by the reactions 64Ni(n,x03B3;) 65Ni, and 58Ni(n,2n)57Ni, respectively. A second 9.04 h isomer, 58mCo, is formed that decays to 70.86-day 58Co. Loss of 58Co and 58mCo by thermal-neutron burnout will occur in environments , having thermal fluence rates of 3 x00D7; 1012 cmx2212;2x00B7;sx2212;1 and above. Burnout correction factors, R, are plotted as a function of time for several thermal fluxes in Fig. 1. Tabulated values for a continuous irradiation time are provided in Hogg, et al. Fig. 2 shows a plot of cross section versus energy for the fast-neutron reaction 58Ni(n,p) 58Co. This figure is for illustrative purposes only to indicate the range of response of the 58Ni(n,p) reaction. Refer to Guide E 1018 for descriptions of recommended tabulated dosimetry cross sections. Note 18212;The data is taken from the Evaluated Nuclear Data File, ENDF/B-VI, rather than the later ENDF/B-VII. This is in accordance with E 1018, section 6.1, since the later ENDF/B-VII data files do not include covariance information. For more details see Section H of reference 8. FIG. 2 58Ni(n,p)58Co Cross Section1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cmx2212;2x00B7;sx2212;1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note8212;The burnup corrections were computed using effective burn-up cross sections of 1650 b for 58Co(n,x03B3;) and 1.4E5 b for 58mCo(n,......
【中国标准分类号】: F74
【国际标准分类号】: 17_240 ; 27_120_30
【页数】: 3P.;A4
【正文语种】: 英语

相关资料