资料描述

【英文标准名称】: Standard Test Method for On-Line Measurement of Low-Level Dissolved Oxygen in Water
【原文标准名称】: 水中低水平溶解氧在线测量的标准试验方法
【标准号】: ASTM D5462-2008
【标准状态】: 现行
【国别】: 美国
【发布日期】: 2008
【实施或试行日期】:
【发布单位】: 美国材料与试验协会(US-ASTM)
【起草单位】: D19.03
【标准类型】: (Test Method)
【标准水平】: ()
【中文主题词】:
【英文主题词】: dissolved oxygen; galvanic cell; oxygen; polarographic sensor; Boiler feedwater; Dissolved oxygen (DO); Galvanic cell; Online monitoring (in water analysis); Oxygen demand (in water); Polarographic methods; Total oxygen demand (TOD)
【摘要】: DO may be either a corrosive or passivating agent in boiler/steam cycles and is therefore controlled to specific concentrations that are low relative to environmental and wastewater treatment samples. Out-of-specification DO concentrations may cause corrosion in boiler systems, which leads to corrosion fatigue and corrosion productsx2014;all detrimental to the life and efficient operation of a steam generator. The efficiency of DO removal from boiler feedwater by mechanical or chemical means, or both, may be monitored by continuously measuring the DO concentration before and after the removal process with on-line instrumentation. DO measurement is also a check for air leakage into the boiler water cycle. Guidelines for feedwater to high-pressure boilers with all volatile treatment generally require a feedwater DO concentration below 5 x03BC;g/L (3). Boiler feedwater with oxygenated treatment is maintained in a range of 50 to 300 x03BC;g/L DO (4). In microelectronics production, DO can be detrimental in some manufacturing processes, for example, causing undesirable oxidation on silicon wafers.1.1 This test method covers the on-line determination of dissolved oxygen (DO) in water samples primarily in ranges from 0 to 500 x03BC;g/L (ppb), although higher ranges may be used for calibration. On-line instrumentation is used for continuous measurements of DO in samples that are brought through sample lines and conditioned from high-temperature and high-pressure sources when necessary. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see 6.5.
【中国标准分类号】: Z16
【国际标准分类号】: 13_060_50
【页数】: 6P.;A4
【正文语种】: 英语